2883 Brighton-Henrietta Townline Road Rochester, NY 14623 Tel: (585) 292-8000 Fax: (585) 424-5619 Email: pulsa@idexcorp.com. Parts purchased to correct a warranty issue may be credited, after an examination of original parts by Pulsafeeder. Warranty parts returned as defective which test good will be sent back freight collect. No credit will be issued on any replacement electronic parts.

The BLACKLINE Series MD is a motor driven, spring return mechanical diaphragm metering pump for precise and accurate metering control. With many standard features, the Series MD includes oil lubricated ball bearings in a die-cast aluminum housing, long life reinforced PTFE diaphragm, micrometer style stroke length adjuster and many liquid end material options to suit any application.
Nine distinct models are available, having flow capabilities to 132 GPH (500 LPH) and pressures to 150 PSI (10 BAR), with a standard turndown ratio of 10:1 or up to 100:1 with the optional VFD Vector. Metering performance is reproducible to within ± 2% of maximum capacity.

Standard Features
• Liquid End Materials – GFPPL, 316 SS & PVDF.
• Rugged double-sided PTFE faced, long life diaphragm.
• Oil lubricated ball bearings in a die-cast aluminum housing.
• Manual micrometer style stroke adjustment; 10:1 turndown or up to 100:1 with the optional VFD Vector.
• Standard NEMA 56C or IEC71 motor frames available. Apowersoft screen recorder for pc free download.
Optional Features
• Variable Frequency Drive for Automatic Control.
• Fully Scalable 4-20mA, 0-10VDC signals.
• NEMA 4X Enclosure.
• ATEX Group II, Category 3 – Zone 2/22 for non-flammable liquids with proper motor selection. Macbook pro task manager.
Pulsafeeder Pumps
General Specifications
VFD Vector
TECH SHEETS
IOMS
DRAWINGS
OTHER DOCUMENTS
Installation operation maintenance instruction, Hydraulic diaphragm metering pump, Bulletin #: pr – iom – 0802 - d
Pulsar 25hj
Bulletin #: PR – IOM – 0802 - D
Installation
Operation
Maintenance
Instruction

Office 2016 for mac setup. Hydraulic Diaphragm Metering Pump

- Introduction
- Principles Of Operation
- Component Location and Operation
- A sealed system must be maintained at all times during pump operation, whether leak detection is required or not. If the proper level of vacuum, between 10 in and 26 in. (250mm to 650mm) Hg, or a sealed pressure system is not present, decreased fl..
- Equipment Inspection
- Storage Instructions
- Installation
- Equipment Setup
- Lubrication
- Drive Motor Installation
- Startup Procedure
- Maintenance
- Oil Changes
- Wet End Removal, Inspection, and Reinstallation
- Check Valves
- Hydraulic Performance Valve (HPV)
- PTP (Push to Purge / Automatic Bleed Valve)
- Piston Seal
- Oil Seals
- Cover Assembly
- Pump Motor
- Replacement Parts
- Troubleshooting Chart
- Appendix I PULSAlarm Leak Detection System
- Leak Detection System Maintenance
- PULSAlarm Leak Detection Diaphragm Maintenance
- Appendix II Piping Calculations
- Appendix III Oil Specifications
- Appendix V Pulsafeeder Accessories
- Pulsatrol Installation, Operation, & Removal Instructions
- Installation
- Pulsatrol Installation, Operation, & Removal Instructions